TM 5-3810-305-23
0005
MALFUNCTION
Valve Not Dispensing Ether.
CORRECTIVE ACTION
1.
Disconnect tube at valve and actuate valve.
2.
MALFUNCTION
Obstruction in Tube to Atomizer.
CORRECTIVE ACTION
Reconnect tube to valve. Actuate valve; if no ether is present, replace tube (WP 0051).
MALFUNCTION
Obstruction in Atomizer.
CORRECTIVE ACTION
Remove atomizer. Reconnect tube to atomizer. Actuate valve. If either is not discharged from
atomizer, it is clogged. Remove atomizer and clean out or replace (WP 0051).
SYMPTOM
ENGINE HARD TO START/WILL NOT START; SMOKE FROM EXHAUST
MALFUNCTION
Cranking Speed Too Low.
CORRECTIVE ACTION
1.
2.
3.
MALFUNCTION
Cold Start Needed.
CORRECTIVE ACTION
Use cold start device (TM 5-3810-305-10).
0005-3
03/15/2011Rel(1.8)root(tswp)wpno(T00010)