TM 5-3810-305-23
FIELD MAINTENANCE
COLD START DEVICE MAINTENANCE
INITIAL SETUP:
References
Tools and Special Tools
Tool Kit, General Mechanic's (WP 0171, Table 1,
Item 17)
Equipment Condition
Boom in horizontal position and fully retracted (TM
Materials/Parts
5-3810-305-10)
Nut, Self-Locking, He M6 (WP 0172, Table 1, Item
138) Qty: 1
Rag, Wiping (WP 0170, Table 1, Item 52) Qty: 1
REMOVAL
1.
Remove cold start cylinder, if equipped.
2.
Loosen screw (Figure 1, Item 9) securing cable end.
3.
Remove screw (Figure 1, Item 10), clamp (Figure 1, Item 2), and disconnect cable (Figure 1, Item 1).
4.
Disconnect tube fitting (Figure 1, Item 8) from elbow (Figure 1, Item 7).
5.
Remove elbow (Figure 1, Item 7) from valve (Figure 1, Item 3).
6.
Remove two nuts (Figure 1, Item 6), bracket (Figure 1, Item 5), valve (Figure 1, Item 3), and two capscrews
(Figure 1, Item 4).
1
2
3
4
5
10
6
9
7
8
M0248105
Figure 1.
Cold Start Device Removal.
03/15/2011Rel(1.8)root(maintwp)wpno(M00057)