• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
'Unknown' by Unknown - Page 176 of 1440
TROUBLESHOOTING PROCEDURES - ELECTRICAL SYSTEM - Continued

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  79    80    81    82    83  84  85    86    87    88    89  
img
. . . . . . . . . . . . . . .
TM 5-3810-305-23
0015
FIELD MAINTENANCE
TROUBLESHOOTING PROCEDURES
ELECTRICAL SYSTEM
INITIAL SETUP:
References (cont.)
Tools and Special Tools
WP 0061
Tool Kit, General Mechanic's (WP 0171, Table 1,
Item 17)
WP 0062
Multimeter (WP 0171, Table 1, Item 29)
WP 0063
Tester, Battery, Electrolyte Solution (WP 0171,
WP 0064
Table 1, Item 12)
WP 0070
WP 0076
WP 0162
References
WP 0166
TM 5-3810-305-10
WP 0059
TROUBLESHOOTING PROCEDURE
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment. Failure to follow this warning may result in injury or death
to personnel.
NOTE
Refer to electrical schematic FO-1 (WP 0166) for aid in troubleshooting electrical system.
SYMPTOM
STARTING MOTOR DOES NOT OPERATE
MALFUNCTION
Ignition Switch OFF.
CORRECTIVE ACTION
Turn ignition switch ON (TM 5-3810-305-10).
0015-1