• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
TROUBLESHOOTING PROCEDURES - ELECTRICAL SYSTEM - Continued
TROUBLESHOOTING PROCEDURES - ANTI-TWO BLOCK SYSTEM - Continued

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  85    86    87    88    89  90  91    92    93    94    95  
img
. . . . . .
TM 5-3810-305-23
0016
FIELD MAINTENANCE
TROUBLESHOOTING PROCEDURES
ANTI-TWO BLOCK SYSTEM
INITIAL SETUP:
References (cont.)
Tools and Special Tools
WP 0067
Tool Kit, General Mechanic's (WP 0171, Table 1,
Item 17)
WP 0070
Multimeter (WP 0171, Table 1, Item 29)
References
TM 5-3810-305-10
TROUBLESHOOTING PROCEDURE
SYMPTOM
PANEL LIGHT AND HORN WILL NOT COME ON WITH ANTI-TWO BLOCK COUNTERWEIGHT LIFTED;
CONTROL DISCONNECTS WILL NOT ENGAGE
MALFUNCTION
Ignition Switch OFF.
CORRECTIVE ACTION
Turn ignition switch ON (TM 5-3810-305-10).
MALFUNCTION
Circuit Breaker Tripped.
CORRECTIVE ACTION
1.
Reset circuit breaker.
2.
If problem still occurs, replace circuit breaker.
MALFUNCTION
Wire Broken.
CORRECTIVE ACTION
1.
Check voltage in control panel harness between terminals #0 and #37.
2.
If voltage is 0, check between ignition post of ignition switch and ground.
3.
If 24 VDC available, wire to control panel is bad.
4.
Replace wire (WP 0067).
0016-1
03/15/2011Rel(1.8)root(tswp)wpno(T00021)