TM 5-3810-305-23
0022
Table 1.
Preventive Maintenance Checks and Services (PMCS) - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
(2) Turn dipstick cap 1/4 turn to safety notch to
relieve pressure.
(3) Remove plug (Figure 5, Item 2), o-ring (Figure
5, Item 3), eight nuts (Figure 5, Item 1), washers (Figure
5, Item 8), cover (Figure 5, Item 4), and o-ring (Figure 5,
Item 5). Discard o-rings.
(4) Remove filter (Figure 5, Item 6) and o-ring
(Figure 5, Item 7) from reservoir. Discard o-rings.
b. Suction Filter Cleaning:
c. Suction Filter Inspection:
d. Suction Filter Installation:
(1) Install new o-ring (Figure 5, Item 7) and filter
(Figure 5, Item 6).
(2) Install new o-ring (Figure 5, Item 5), cover
(Figure 5, Item 4), eight washers (Figure 5, Item 8), nuts
(Figure 5, Item 1), new o-ring (Figure 5, Item 3), and plug
(Figure 5, Item 2).
(3) Close dipstick cap. Operate crane at part throttle
to slightly pressurize the reservoir.
(4) Bleed out all air by loosening plug (Figure 5, Item
2). Tighten plug.
0022-8