TM 5-3810-305-23
0022
Table 1.
Preventive Maintenance Checks and Services (PMCS) - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
d. Loosen plug located at the bottom of fuel tank
and drain until fuel runs clearly and no water remains.
e. Install drain plug and refill fuel tank.
DRAIN PLUG
M0840105
Figure 4. Fuel Tank Drain Plug.
6
Four-Month Clean Hydraulic
a. Suction Filter Removal:
Check or
Suction Filter
Every 500
Hours of
Service
WARNING
Never disconnect hydraulic lines or fittings
before venting pressure. Turn dipstick cap
1/4 turn to safety notch to relieve pressure.
Failure to follow this warning may cause
death or injury to personnel.
03/15/2011Rel(1.8)root(pmcswp)wpno(I00027)