Figure 1. Radiator and Oil Cooler Removal.
Figure 3. Radiator and Oil Cooler Removal.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  337    338    339    340    341  342  343    344    345    346    347  
img
.
TM 5-3810-305-23
0054
REMOVAL - Continued
WARNING
Never disconnect hydraulic lines or fittings before venting pressure. Turn dipstick cap 1/4 turn
to safety notch to relieve pressure. Failure to follow this warning may cause death or injury
to personnel.
4.
Turn dipstick cap 1/4 turn to safety notch.
NOTE
Tag all hose and tube assemblies before disconnecting to aid in installation.
Cap and plug all hoses, tubes, and ports to reduce fluid leakage and
system contamination.
Remove caps, plugs, and tags prior to installation.
5.
Disconnect hose (Figure 2, Item 1) and hose (Figure 2, Item 3) on front of oil cooler (Figure 2, Item 2).
2
3
1
M0075105
Figure 2. Radiator and Oil Cooler Removal.
0054-3