TM 5-3810-305-23
0110
INSPECTION
Inspect parts IAW General Maintenance Instructions (WP 0162).
END OF TASK
ASSEMBLY
CAUTION
Keep new seal package free of particles of lint, felt, and dirt. Failure to follow this caution can
cause new seal package to leak, damaging equipment.
NOTE
Clean input shaft of control unit and upper cover seal bore to remove particles of dirt, felt and
lint with a clean, lint-free rag.
1.
Cover control unit (Figure 3, Item 3) shaft with cellophane tape to protect new seal package (Figure 3, Item 5).
2.
Lubricate new seal package (Figure 3, Item 5) with hydraulic oil and install and control unit (Figure 3, Item 3)
shaft lip side first.
3.
Remove cellophane tape.
4.
Install new seal package (Figure 3, Item 5) with small end first on control unit (Figure 3, Item 3) shaft.
5.
Using deep-well socket push new seal package (Figure 3, Item 5) washer down into upper cover of control
unit (Figure 3, Item 3).
6.
Install retaining ring (Figure 3, Item 2) on control unit (Figure 3, Item 3) shaft and push down into upper groove
in control unit cover.
7.
Install new dirt seal (Figure 3, Item 1) on control unit (Figure 3, Item 3) shaft and press down into control unit
upper cover.
0110-4
03/15/2011Rel(1.8)root(maintwp)wpno(M00123)