Figure 1. Outrigger Cylinder Removal.
Figure 3. Outrigger Cylinder Removal.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  1019    1020    1021    1022    1023  1024  1025    1026    1027    1028    1029  
img
.
TM 5-3810-305-23
0151
REMOVAL - Continued
WARNING
Never disconnect hydraulic lines or fittings before venting pressure. Turn dipstick cap 1/4 turn
to safety notch to relieve pressure. Failure to follow this warning may cause death or injury
to personnel.
5.
Turn dipstick cap 1/4 turn to safety notch to relieve pressure.
NOTE
Tag all hose and tube assemblies before disconnecting to aid in installation. Cap and plug
all ports. Remove caps, plugs, and tags following maintenance.
6.
Remove two capscrews (Figure 2, Item 5), lockwashers (Figure 2, Item 4), hold valve (Figure 2, Item 3), and
two o-rings (Figure 2, Item 2) from outrigger cylinder (Figure 2, Item 1). Discard lockwashers and o-rings.
1
2
3
4
5
4
M0447105
Figure 2.
Outrigger Cylinder Removal.
0151-3
03/15/2011Rel(1.8)root(maintwp)wpno(M00167)