TM 5-3810-306-10
TABLE 3-1. OPERATOR TROUBLESHOOTING (CONTD)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
51. ERROR CODE E05 ON LMI MOMENT DISPLAY
Step 1.
Maximum or minimum boom length exceeded.
a. Telescope boom to correct length given in load chart. Refer to Appendix F.
Step 2.
Load moment indicator system malfunction.
a. Contact Direct Support Maintenance.
52. ERROR CODE E80 ON LMI LOAD DISPLAY
Step 1.
Indicates load on hook is below 9,000 lbs.
a. No corrective action required. Information code only.
53. ERROR CODE EEE ON LMI MOMENT DISPLAY
Step 1.
Actual load exceeds 200% of rated machine capacity at a given operating condition.
a. Correct to operate within approved load chart and operating conditions. Refer to Appendix F.
Step 2.
Load moment indicator system malfunction.
a. Contact Direct Support Maintenance.
END OF TASK
3-24