TM 5-3810-306-10Table 2-2. Load Moment Indicator (Cont’d)KeyControl or IndicatorFunction5 - Test. Lights all lampsand sounds horn. MOMENTdisplay (2) and datadisplay (3) show"-188.8" and LOADdisplay shows "88880".Dangerous crane movementbeing performed duringtest will stop.WARNINGSelecting the correct number of line parts is critical to theoperation of the load moment indicator. Selecting thewrong number will result in faulty indications andpossible personnel injury or equipment damage.5Reeving Selector SwitchSelect number 1 thru 6 tocorrespond to number ofparts of line being used.The container crane with thestandard hook block is a six(6) part configuration.With the overhaul ball, theline is one (1) part.6A2B Red indicator lightLights when anti-twoblock(A2B) switch is trippedcausing the system tolockout craning operations.785% Yellow indicator lightLights when crane is lifting85% of its rated capacity.Warning does not lock outoperations.895% Red indicator lightLights when crane is lifting95% of its rated capacity.An audible alarm will alsosound. Warning does notlock out craning operations.2-12
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business