TM 5-3810-306-10
Table 2-2. Load Moment Indicator (Contd)
Key
Control or Indicator
Function
10
STATIONARY/PICK & CARRY
STATIONARY - Select this
Selector switch
position when performing
craning operations with the
crane standing still.
PICK & CARRY - Select this
position when performing
craning operations with the
crane moving.
WARNING
Before using the CLL-OVERRIDE be aware that you are
disabling a safety device: The automatic control lever
lockout system. Do not assume that safety devices
installed on this crane have failed when craning
operations "appear" to be within crane operating
capacities when the alarm occurs investigate first!
Failure to observe this warning could result in personnel
injury and/or equipment damage.
11
CLL - OVERRIDE Momentary
UP - When alarm is on,
Selection Switch
overrides audible alarm for
15 seconds.
CLL- OVERRIDE - Depress and
hold to override the load
moment indicator and anti-
twoblock. Enables the
operator to override the
automatic control lever
lockout system. Release
switch to reactivate the
protective system.
END OF TASK
2-14