TM 5-3810-306-10OPERATOR PMCS (CONTD)INTERVALITEMNO.BDAWMITEM TO BE INSPECTEDPROCEDURE: CHECK FOR AND HAVEREPAIRED, FILLED, OR ADJUSTEDEQUIPMENT IS NOTREADY/AVAILABLE IF:d. Check that display of mainboom length agrees with theactual boom length.e. Check that display of mainboom angle agrees with actualangles.f. Check that display of craneoperating radius agrees withactual radius.NOTEAfter being properly set, theoperation of the LMI is fullyautomated. Therefore, the operatormust be thoroughly familiar with allcontrols of the LMI and mustproperly set each switch beforeoperating the crane. All settingsmust be checked by lifting a load ofknown weight and comparing the loadto the information displayed on theload moment indicator.Rated loads include the weight ofslings and auxiliary lifting devicesand their weights shall be subtractedfrom the listed ratings to obtain thenet load to be lifted.26BATTERIESWARNINGDo not smoke or allow flame orspark in the vicinity whilechecking or filling the batteries.The batteries generate hydrogen -a highly explosive gas. Wear safetygoggles when adding distilled water.2-26