TM 5-3810-306-10OPERATOR PMCS (CONTD)INTERVALITEMNO.BDAWMITEM TO BE INSPECTEDPROCEDURE: CHECK FOR AND HAVEREPAIRED, FILLED, OR ADJUSTEDEQUIPMENT IS NOTREADY/AVAILABLE IF:NOTESee item 27 to check function ofBoom Angle Indicator.NOTEIf you cannot clearly see thehook block approaching the boom,you should have an assistant watchthe hook block. You should beprepared to stop the craneimmediately if the LMI systemdoes not function properly bylighting the red warning light,sounding the audible alarm andlocking the dangerous cranemovements.a. Check anti-twoblock alarm lightand audible alarm by manuallylifting the weight attached toanti-twoblock switches.b. Slowly raise the main boom hookblock to bring it into contact withswitch weight. When the hookblock lifts weight, audible alarmshould sound; anti-twoblock alarmlight should light and motion ofhook block should be stopped.Lower hook block slightly toeliminate this condition.c. Slowly lower or extend boom tocreate a potential two-blockcondition. When hook block liftsweight, alarm should sound, anti-twoblock alarm light shouldlight and boom lowering and/orboom extension function shouldbe stopped.NOTE: If the light and audiblealarm do not function asdescribed and the crane move-ments are not stopped, thesystem is not working properly.The malfunction must becorrected before operatingthe crane.Change 1 2-25