TM 5-3810-306-10
OPERATOR PMCS (CONTD)
INTERVAL
ITEM
NO.
B
D
A
W
M
ITEM TO BE INSPECTED
PROCEDURE: CHECK FOR AND HAVE
REPAIRED, FILLED, OR ADJUSTED
EQUIPMENT IS NOT
READY/AVAILABLE IF:
CAUTION
In cold operation, charge batteries
immediately after water has been
added to prevent freezing and damage
to batteries; run crane engine for
one hour at 1500 rpms.
·
a. Check the electrolyte level.
Batteries will not
Electrolyte level should be
crank engine.
above the plates and below
the fill hole.
·
b. Check battery cables and
Batteries will not
connections for corrosion.
crank engine.
·
c. Check battery box for damage
and corrosion.
27
·
Mechanical
Boom Angle
Indicator and
LMI lockout.
a. Check for proper
operation. Raise
boom to verify that
light and error code
occurs on LMI
console. Refer to
Appendix G.
b. While raising boom,
Mechanical boom
verify that
angle indicator is
mechanical angle
inoperative,
indicator moves
missing, or
from 0 to 70
binds/sticks.
without sticking or
binding.
Change 1 2-27