TM 5-3810-306-20
INSTALLATION:
1.
INSTALL NEW EMERGENCY STEER PUMP
CABLE(S).
a.
As required, install hex nuts (2) (hex nut (7), new
lockwasher (8) and flatwasher (9) for ground
cable) to cable terminals (3) for each new cable.
b.
Coat terminals and connectors with anti-
corrosion compound or grease.
2.
SECURE RELAY COVER (1) USING WASHERS
(6), NEW LOCKWASHERS (5) AND NUTS (4).
3.
CONNECT GROUND CABLE AT SHUNT. (REFER
TO PAGE 8-109.)
4.
INSTALL BATTERY COVER. (REFER TO PAGE
8-98.)
END OF TASK
8-106