TM 5-3810-306-20
EMERGENCY STEER PUMP CABLE(S) REPLACEMENT
TOOLS: General mechanics tool kit: automotive (5180-00-177-7033)
SUPPLIES:
Lockwashers (Item 2, Appendix C) (2 Required)
Lockwasher (Item 57, Appendix C)
EQUIPMENT CONDITIONS: Disconnect ground cable at shunt. (Refer to page 8-109.)
Battery cover removed. (Refer to page 8-98.)
REMOVAL:
WARNING
Batteries generate explosive gases.
Keep sparks, flames or other ignition
sources away at all times. Always
shield
eyes
when
working
near
batteries.
WARNING
Electrolyte splashed into eyes is
extremely dangerous. If this should
happen, force eye open and flood
with
cool,
clean
water
for
approximately five minutes. Call for
immediate medical attention.
1.
REMOVE RELAY COVER (1) IF REQUIRED.
a.
Remove nuts (4), lockwashers (5) and washers
(6). Discard lockwashers (5).
b.
Remove relay cover (1).
2.
REMOVE EMERGENCY STEER PUMP CABLE(S).
a.
As required, remove hex nuts (2) (hex nut (7),
lockwasher (8) and flat washer (9) for ground
cable) on cable terminals (3) for each cable.
Discard lockwasher (8) if removed.
b.
Remove and inspect cable(s). Replace parts as
required.
8-105