TM 5-3810-306-20EMERGENCY STEER PUMP CABLE(S) REPLACEMENTTOOLS: General mechanic’s tool kit: automotive (5180-00-177-7033)SUPPLIES:Lockwashers (Item 2, Appendix C) (2 Required)Lockwasher (Item 57, Appendix C)EQUIPMENT CONDITIONS: Disconnect ground cable at shunt. (Refer to page 8-109.)Battery cover removed. (Refer to page 8-98.)REMOVAL:WARNINGBatteries generate explosive gases.Keep sparks, flames or other ignitionsources away at all times. Alwaysshield eyes when working nearbatteries.WARNINGElectrolyte splashed into eyes isextremely dangerous. If this shouldhappen, force eye open and floodwith cool, clean water forapproximately five minutes. Call forimmediate medical attention.1.REMOVE RELAY COVER (1) IF REQUIRED.a.Remove nuts (4), lockwashers (5) and washers(6). Discard lockwashers (5).b.Remove relay cover (1).2.REMOVE EMERGENCY STEER PUMP CABLE(S).a.As required, remove hex nuts (2) (hex nut (7),lockwasher (8) and flat washer (9) for groundcable) on cable terminals (3) for each cable.Discard lockwasher (8) if removed.b.Remove and inspect cable(s). Replace parts asrequired.8-105