TM 5-3810-306-20
WARNING (CONTD)
Avoid contact with skin, eyes, and
clothes and dont breathe vapors. Do
not use near open flame or excessive
heat. The flash point is 100°F138°F
(380-590C). If you become dizzy
while using cleaning solvent, get
fresh air immediately and get medical
aid. If contact with eyes is made,
wash your eyes with water and get
medical aid immediately.
Compressed air used for cleaning
purpose will not exceed 30 psi. Use
only with effective chip guarding and
personal
protective
equipment
(goggles/shield, gloves, etc.).
1.
CLEAN ALL PARTS WITH P-D-680. DRY PARTS
WITH LOW PRESSURE COMPRESSED AIR.
INSPECTION:
1.
INSPECT ALL PARTS FOR DAMAGE AND
REPLACE AS NECESSARY.
REASSEMBLY:
1.
REASSEMBLE OVERHAUL BALL.
a. Install hook (17) through bottom housing (15)
and secure with thrust bearing (14) and nut (13).
Install setscrew (12).
b. Install grease fitting (10), if removed.
c. Screw bottom housing (15) with hook (17) into
top housing (16). Install setscrew (11).
d. Install centering ring (9) and secure with
setscrew (18).
e. Position swivel hook and top housing (9) thru
(10) into overhaul ball.
2.
INSTALL OVERHAUL BALL. (REFER TO PAGE
17-4.)
END OF TASK
17-6