TM 5-3810-306-20WARNING (CONT’D)Avoid contact with skin, eyes, andclothes and don’t breathe vapors. Donot use near open flame or excessiveheat. The flash point is 100°F138°F(380-590C). If you become dizzywhile using cleaning solvent, getfresh air immediately and get medicalaid. If contact with eyes is made,wash your eyes with water and getmedical aid immediately.Compressed air used for cleaningpurpose will not exceed 30 psi. Useonly with effective chip guarding andpersonal protective equipment(goggles/shield, gloves, etc.).1.CLEAN ALL PARTS WITH P-D-680. DRY PARTSWITH LOW PRESSURE COMPRESSED AIR.INSPECTION:1.INSPECT ALL PARTS FOR DAMAGE ANDREPLACE AS NECESSARY.REASSEMBLY:1.REASSEMBLE OVERHAUL BALL.a. Install hook (17) through bottom housing (15)and secure with thrust bearing (14) and nut (13).Install setscrew (12).b. Install grease fitting (10), if removed.c. Screw bottom housing (15) with hook (17) intotop housing (16). Install setscrew (11).d. Install centering ring (9) and secure withsetscrew (18).e. Position swivel hook and top housing (9) thru(10) into overhaul ball.2.INSTALL OVERHAUL BALL. (REFER TO PAGE17-4.)END OF TASK17-6