TM 5-3810-307-10
Override Key Warning Light
The red OVERRIDE KEY WARNING LIGHT (5) flashes to
indicate that the cut-off function of the A2B I LMI system is
deactivated.
Button and Control Light "Alarm Stop"
This ALARM STOP BUTTON (6) allows the audible alarm to be
silenced for approximately 15 seconds by pressing this button.
Reference "Audible Alarm" (12).
Button and Control Light "Tare"
The button "TARE" (7) is used to indicate the "Net load" on the
LC Display (1). Net load is the present load, less lifting tackle
and hook block. The Tare Button (7) must be activated before
lifting.
After pushing the "Tare Button" (7) the load display is set to zero
(taring) and the control light lights up. After lifting a load the
display shows the net load (pay load).
The net load display will change to the actual load display when
the boom radius is changed (either by angle or length).
Button "LIMITS"
Button to start the function "program limit values".
Change 1 G-11