TM 5-3810-307-10
The LMI setup procedure allows the operator to input the crane configuration using
interactive displays. The operator must complete the setup procedure for the Load Moment
Indicator system if the system has been turned off for more than two hours or the crane
operation configuration has been changed.
...starts:
automatically, if the system
was turned off for more than
two hours.
manually at each modification
of the crane configuration by
pressing key (9) "SEL"
...is operated:
by answering the different
questions using functional
keys F1...F4 in accordance
with the actual configuration
of the crane.
...is cancelled:
any time by pressing again
key (9) "SEL". The system,
however, is only ready for
operation, if the procedure
has been completed and the
inputs have been confirmed.
If the system is turned off less than two hours (during short breaks), all adjustments remain
stored. When turning the system on again these adjustments can be acknowledged by
merely pressing the "OK" function if the crane configuration has not been modified.
NOTE
During low temperatures the LC Display will not show the graphics, or become
operational, until the display console heater has warmed the electronics.