TM 5-3810-307-24-1-1
BACKUP ALARM (SUPERSTRUCTURE)
Removal
a.
Ensure battery disconnect switch is in the OFF position.
b.
Tag electrical leads and disconnect superstructure electrical harness lead from backup alarm (4, Figure 2-14-
14).
c.
Remove nuts (1), lockwashers (2), washers (3), ground wires, backup alarm (4), and washers (5) from
superstructure frame.
Installation
a.
Position washers (5, Figure 2-14-14) and backup alarm (4) on studs on superstructure frame.
b.
Place ground wires from backup alarm (4) and superstructure electrical harness on stud at terminal side of
backup alarm.
c.
Secure backup alarm (4) to carrier frame with washers (3), lockwashers (2), and nuts (1).
d.
Connect superstructure electrical harness lead to backup alarm (4).
LEGEND
1.
Nut
3
Washer
5. Washer
2.
Lockwasher
4. Backup alarm
Figure 2-14-14 Backup Alarm Installation (Superstructure)