    ERROR CODE DISPLAY - Continued
    DRAWING 1. ELECTRICAL WIRING CENTRAL UNIT TO CRANE/PRESSURE TRANSDUCERS

    Maintenance Manual For All-Terrain Crane (ATEC) Diesel Driven, 22 Ton - Vol 1 - Pt2 Page Navigation
      478    479    480    481    482  483  484    485    486    487    488  
    img
    TM 5-3810-307-24-1-2
    ERROR ERROR
    CAUSE
    ACTION
    CODE
    E95
    Error in the crane
    a.) Data EPROM is
    a.) Replace data EPROM.
    data EPROM
    defective.
    b.) Position of jumper for the
    b.) Check the jumper position.
    selection of the type of
    EPROM is wrong.
    c.) Electronics component on
    c.) Replace main board and
    the main board is defective.
    reset pressure channels. See
    Drawing 3 & Procedures 3 & 4.
    E96
    Error in the internal
    CPU or main board of the
    Replace console main board.
    RAM of the CPU of
    console is defective.
    the console
    a.) Replace console main
    E97
    Error in the external
    a.) External RAM of the
    console is defective.
    board.
    RAM of the CPU of
    b.) Electronic component on
    the console
    b.) Replace console main
    the main board is defective.
    board.
    E98
    Wrong jumper
    a.) The jumper position BR
    a.) Check the jumper position.
    position in the
    9/BR 10 in the console does
    console
    not correspond to the actual
    type of central unit.
    b.) Electronic component on
    b.) Replace console main
    the main board is defective.
    board.
    G-32 Change-1