TM 5-3810-307-24-1-2
9. ERROR CODE DISPLAY
PROBLEM: Error code displayed. Lever lockout activated. Warning Lights on.
ERROR ERROR
CAUSE
ACTION
CODE
Minimum radius or
Fallen below the minimum
Lower boom back to a radius or
E01
maximum angle
radius or above the angle
angle given in the load chart.
range exceeded
given in the load chart due to
raising the boom too far.
Maximum radius or
The maximum radius or
Raise boom back to a radius or
E02
minimum angle
minimum angle given in the
angle given in the load chart.
range exceeded
load chart was exceeded
due to lowering the boom too
far.
Operating mode not
Operating mode switch in
Set operating mode switch
E04
available
the console set incorrectly.
correctly to the code assigned
Operating mode is not
to the operating mode of the
permissible with actual crane
crane.
configuration.
Length range not
Boom has been extended
Retract or extend boom to
E05
permitted
too far or not far enough.
correct length given in the load
Length sensor adjustment
chart. See Section 6.
changed; i.e. length sensor
cable slid off the cable drum.
No acknowledgment
Replace relay.
E07
signal from overload
defective or not being
selected.
No acknowledgment
Anti-two block switch relay is
Replace relay.
E08
signal from anti-two
defective or not being
block switch relay
selected.
(K2)
Fallen below limit for
a.) Cable between length
E11
a.) Check cable and connector
the measuring
sensor and central unit is
as well and replace, if
channel "length"
defective, not connected or
necessary. Section 6.
water in the connectors.
b.) Replace and reset length
sensor potentiometer. See
b.) Length sensor is
Section 6 & Procedure 5.
potentiometer defective.
c.) Replace main board and
c.) Electronic board in the
reset pressure channels. See
measuring channel is
Drawing 3 & Procedures 3 & 4.
defective.