DRAWING 16. CONNECTION BOARD IN CENTRAL UNIT
DRAWING 18. CONNECTION BOARD IN CENTRAL UNIT

Maintenance Manual For All-Terrain Crane (ATEC) Diesel Driven, 22 Ton - Vol 1 - Pt2 Page Navigation
  497    498    499    500    501  502  503    504    505    506    507  
img
.
TM 5-3810-307-24-1-2
10. DRAWING 17. CABLE REEL TERMINAL BOARD W/VOLTMETER
ON TERMINALS 1 & 2 AND ON TERMINALS 1 & 3
THE VOLTMETER SHOULD MEASURE 5.0 VOLTS BETWEEN TERMINALS 1
(GROUND) AND 3 (SUPPLY VOLTAGE) VOLTMETER NOT SHOWN
THE VOLTMETER SHOULD MEASURE THE FOLLOWING BETWEEN TERMINALS 1
(GROUND) AND 2 (SIGNAL VOLTAGE):
 0.5  VOLTS  WITH  THE  BOOM  FULLY  RETRACTED  AND  LENGTH
POTENTIOMETER SET FULLY COUNTERCLOCKWISE TO A SOFT STOP
(MINIMUM SENSOR OUTPUT)
 2.1 VOLTS ( 0.1 V) WITH THE BOOM FULLY EXTENDED (ACTUAL WORKING
RANGE)
 4.5 VOLTS WITH THE LENGTH POTENTIOMETER TURNED COMPLETELY
CLOCKWISE 10 TURNS TO A SOFT STOP (MAXIMUM SENSOR OUTPUT)
NOTE
REFER TO DRAWING 2 FOR WIRING DIAGRAM.
Change-1 G-51