Electrical Connections Seven Day Timer
Figure J-16. Engine Coolant Flow Diagram

Maintenance Manual For All-Terrain Crane (ATEC) Diesel Driven, 22 Ton - Vol 1 - Pt2 Page Navigation
  611    612    613    614    615  616  617    618    619    620    621  
img
. .
TM 5-3810-307-24-1-2
g.
Install a terminal (7) on one end of the jumper wire (6).
h.
Twist the brown wire from the cable (5) and the other end of the jumper wire (6)
together, install a terminal (7) on end, and crimp to secure.
i.
Install terminals (7) on the red, blue/white, and yellow wires and crimp to secure.
j.
Install terminals in appropriate terminal locations on plastic connector body (8) in
accordance with the Table J-1.
k.
Connect to the seven day timer (4) connector.
Table J-1. Seven Day Timer Connector Terminal Designations
Connector View - Cable input
side (viewed from behind)
Term.
Designation
Wire Color
1
-
-
2
S+ Switch On Signal
Yellow Wire
3
-
-
4
TRS/TMD Mode Deactivation
Brown Jumper
1 4 7 10
5
-
-
6
-
-
2 5 8 11
7
-
-
8
Diagnosis
Blue/White Wire
3 6 9 12
9
-
10
-
1
Terminal 30 (+) Supply 5A
Red Wire
12
Terminal 31 (1) Supply
Brown Wire and Jumper
J-30 Change-1