TM 5-3810-307-24-1-2
Disassembly
a.
Remove the four base plate retaining screws (1, Figure K-13) securing the base plate (2)
to the blow count recorder housing (3). Remove the base plate (2) and gasket (4) from
the blow count recorder housing (3).
b.
Pull on the free end of the screening to remove the blow count recorder (5) and battery
pack (6), in their protective foam (7), from the blow count recorder housing (3).
c.
Remove the blow count recorder (5) from the protective foam (7).
d.
Disconnect the electrical connector (8) on the battery pack (6) from the blow count
recorder (5) and remove the battery pack (6) from the protective foam (7).
3
7
5
6
8
4
2
1
LEGEND
1.
Base Plate Retaining Screws,
5.
Blow Count Recorder
1/4 x 3/4 NC SHCS
6.
Battery Pack
2.
Base Plate
7.
Protective Foam
3.
Blow Count Recorder Housing
8.
Electrical Connector
4.
Gasket
K-38 Change-1