13-44. Cleaning, Inspection and Repair
(1) Install grommets (9) in battery case (10).
a.
Clean all metal parts with cleaning solvent,
(2) Set retainers (8) in case (10) and install hook
Federal Specification P-D-680, or equivalent.
bolts (7). Secure with flat washers (6), lock washers (5)
b.
Inspect all parts for damage. Check all seams
and nuts (4).
for cracks. Replace all defective parts.
(3) Place cover (3) on case (10) and latch in place.
13-45. Reassembly and Installation
(4) Slide hose (2) on case (10) and secure with
a.
Refer to figure 13-17 and reassemble the
clamp (1).
battery box as follows:
b. Refer to TM 5-3810-295-12 and install battery
box assembly.
Section XI. REPAIR OF INSTRUMENT BOARD ASSEMBLY
remove starter switch cup and plunger assembly (5).
13-46. Removal and Disassembly
Remove switch base (3) and gasket (4).
a. Refer to TM 5-3810-295-12 and figure 13-18 and
(3) Remove nuts (9), lock washers (10) and
remove the instrument board assembly from the
screw
carrier as follows:
(11). Remove circuit breaker (12) from instrument
(1) Disconnect and tag all electrical leads to the
panel.
instrument panel.
(4) Remove light indicator socket (13), lamp (14)
(2) Remove screws (57, fig. 13-18), lock
cable (15) and plug connectors (16).
washers (58) and nuts (59).
(5) Remove light indicator socket (17), lamp (18),
(3) Remove screws (60), lock washers (61) and
cable (19) and plug connectors (20).
nuts (62) and lift instrument board from carrier
(6) Remove screws (21) and pull toggle switch
cab.
(22) from left panel (55).
b. Refer to figure 13-18 and disassemble the instru-
(7) If damaged, remove warning plate (23).
ment board assembly.
Remove speedometer (24), pressure indicator (25),
(1) Remove screws (1) and remove light switch
temperature indicator (26) and voltage indicator (27).
(2) from instrument panel.
(2) Remove nut (8), lock washer (7) and nut (6)
and
13-34