TM5-3810-305-10
Weight of (component) is ap-
proximately XX lb (XX kg). Use
two people to properly support
and lift (component). Failure to
follow this procedure could cause
DEATH or serious injury.
Unwarranted use of BY-PASS
switch can result in damage to
the LRT 110 Crane and cause
DEATH or serious injury.
Cooling system is pressurized.
Use extreme caution and proper
protection when removing
radiator cap after operating
temperature is reached. When
removing cap, loosen it slowly to
the left, then pause a moment.
Steam and hot gases will be
escaping through the radiator
cap; avoid being burned by these
gases. Continue to turn cap until
it can be removed. Failure to
follow this procedure could cause
SERIOUS INJURY.
l Battery gases can explode. Do not
smoke or allow sparks or open flames
near batteries. Wear safety glasses or
goggles when checking the batteries.
Failure to follow this procedure could
cause DEATH or serious injury.
corrosion or electrolyte makes contact,
take immediate action to stop the
burning effects:
EYES: Flush with cold water for
no less than 15 minutes and seek
medical attention immediately.
SKIN: Flush with large amounts
of cold water until all acid is
removed. Seek medical attention
as required.
INTERNAL: If corrosion or
electrolyte is ingested, drink
large amounts of water or milk.
Follow with milk of magnesia,
beaten egg or vegetable oil. Seek
medical attention immediately.
CLOTHING/EQUIPMENT:
Wash area with large amounts of
cold water. Neutralize acid with
baking soda or household ammo-
nia.
Failure to follow this procedure
could cause DEATH or serious
injury.
The operator must exercise sound
judgment in positioning outrig-
gers. The outriggers should not
be set near holes, on rocky
ground or on extremely soft
ground. Setting outriggers in
such locations may result in the
vehicle tipping, causing DEATH
or serious injury.
l Sulfuric acid contained in batteries can
cause serious bums. If battery
1-29