TM5-3810-305-10
Preventive Maintenance Checks and
Services (PMC)
The following Preventive Maintenance Checks
and Semites (PMCS) should be followed regu-
larly to maintain the LRT 110 Crane at peak
operating condition. Perform PMCS more often
to compensate for continuous operation or under
abnormal conditions (i.e., extreme cold or heat;
exposure to moisture or salt; operation in dust or
sand).
Daily Check or Every 8 Hours of Service
Check hydraulic reservoir fluid level (refer to
lubrication chart, Appendix B, and page 4-10).
Fill fuel tank (refer to page 4-10).
Check engine oil level (refer to page 4-10).
Check coolant level (refer to page 4-10).
Check air cleaner (refer to page 4-11).
Check hydraulic components.
Make overall visual inspection, including
ground, for leakage.
Check brake fluid (refer to page 4-11).
Verify that tires are inflated properly (refer to
page 1-20).
Check for dirt accumulation in outrigger box.
Drain fuel/water separator (refer to page 4-10).
CAUTION
If any gauge fails to operate, shut
engine off and notify mainte-
nance. Failure to follow this
procedure could cause damage to
equipment.
Check instruments, gauges and safety equipment
using the following procedure :
1.
2.
3.
4.
Start engine. Check to see if all gauges are
operational.
Check all lights, warning horns, mirrors and
turn signals.
Check all controls for proper operation. Con-
trols should move smoothly, without binding
or excessive free play.
Check transmission oil level (refer to page 4-
10).
Check anti-two block system (refer to page 4-
11).
Check cable and related equipment (refer to page
4-11).
Lubricate rear axle pivot and axle lockout cylin-
ders. Raise crane on outriggers before greasing
(refer to lubrication chart, Appendix B).
Lubricate turntable gear and pinion gear teeth
(refer to lubrication chart, Appendix B).
Weekly Check or Every 40 Hours of Service
Perform the Daily Check.
Perform Daily and Weekly lubrication (refer to
lubrication chart, Appendix B).
4-13