• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
STARTER MOTOR MAINTENANCE
STARTER MOTOR MAINTENANCE - Continued

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  385    386    387    388    389  390  391    392    393    394    395  
img
. . .
TM 5-3810-305-23
0063
CLEANING
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT directed compressed air against human skin. Failure to follow
this warning may result in injury. Make sure air stream is directed away from user and
other personnel in the area. To prevent injury, personnel must wear protective goggles or
face shield.
Clean parts IAW General Maintenance Instructions (WP 0162).
END OF TASK
INSPECTION
Inspect parts IAW General Maintenance Instructions (WP 0162).
END OF TASK
INSTALLATION
1.
Position starting motor (Figure 2, Item 3) on engine and install clip (Figure 2, Item 1) and three capscrews
(Figure 2, Item 4). Tighten capscrews to 32 ft-lb (43 Nm).
2.
Connect wires and cables to starting motor solenoid (Figure 2, Item 2).
1
2
3
4
M0115105
Figure 2.
Starter Motor Assembly.
END OF TASK
0063-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00069)


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.