TM 5-3810-305-23
0115
INSTALLATION
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment.
Wear protective eye covering. Serious injury to personnel may result from flying metal
fragments.
Wear protective gloves when handling hot parts.
Failure to follow these warnings may result in injury or death to personnel.
1.
Position hook block tieback on mounting plate as shown.
2.
Tack weld in place.
3.
Weld in place with 0.25 inch (6.4 mm) fillet weld and groove weld as shown. Use the following American Welding
Society procedures:
SMAW (Shielded Metal Arc Welding) - Use AWS E7018 or El 1018 electrode.
GMAW (Gas Metal Arc Welding) - Use AWS E70T-1 Flux Core electrode or E70S-3, E70S-6 Type
Solid electrode.
FCAW (Flux Core Arc Welding) - Use AWS E70T-1 Flux Core electrode or E70S-3, E70S-6 Type
Solid electrode.
M0593105
Figure 2.
Hook Block Tieback Installation.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00128)