• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
OUTRIGGER SOLENOID VALVE MAINTENANCE
Figure 1. Outrigger Solenoid Valve Removal.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  909    910    911    912    913  914  915    916    917    918    919  
img
TM 5-3810-305-23
0136
REMOVAL
WARNING
Never disconnect hydraulic lines or fittings before venting pressure. Turn dipstick cap 1/4 turn
to safety notch to relieve pressure. Failure to follow this warning may cause death or injury
to personnel.
1.
Turn dipstick cap 1/4 turn to safety notch to relieve pressure.
NOTE
Tag all wire assemblies before disconnecting to aid in installation. Remove tags
following maintenance.
2.
Disconnect four electric wires connected to outrigger solenoid valve (Figure 1, Item 4).
NOTE
Tag all hose and tube assemblies before disconnecting to aid in installation. Cap and plug
all ports. Remove caps, plugs and tags following maintenance.
3.
Disconnect three hoses (Figure 1, Item 1), remove three elbows (Figure 1, Item 2), and o-rings
(Figure 1, Item 3) from outrigger solenoid valve (Figure 1, Item 4). Cap hoses and plug holes in outrigger
solenoid valve. Discard o-rings.
4.
Remove four nuts (Figure 1, Item 7), washers (Figure 1, Item 8), and capscrews (Figure 1, Item 6) from
mounting brackets (Figure 1, Item 5). Remove outrigger solenoid valve (Figure 1, Item 4) from outrigger box.
0136-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00152)


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.