TM 5-3810-306-20
CAUTION
Water pressure from a hose or tap
should
not
exceed
40
psi
(276
kPa/2.76 Bar).
CAUTION
Never use gasoline or solvents to
clean the elements.
NOTE
Never
clean
the
safety
element.
Replace the safety element after
cleaning the primary element three
times.
1.
CLEAN
PRIMARY
ELEMENT
(5)
IN
WATERDETERGENT SOLUTION OR BLOW OUT
WITH COMPRESSED AIR.
NOTE
If primary element is cleaned with
compressed air, element can be put
back
into
service
immediately;
however, if cleaned by washing,
element
must
be
dried
before
returning it to service.
NOTE
Primary
elements
are
partially
covered by a plastic sleeve with fins.
The covered portion can be cleaned
with water or air without removing
the sleeve. Use a stiff fiber (not wire)
brush to remove oil and grease
deposits from the sleeve and fins.
Never remove the sleeve and fins
from the element.
5-5