TM 5-3810-306-20
eyes with water and get medical aid
immediately.
Compressed air used for cleaning
purposes will not exceed 30 PSI. Use
only
effective
chip
guarding
and
personal
protective
equipment
(goggles/shield, gloves, etc.).
2.
CLEAN ALL PARTS WITH P-D-680. DRY PARTS
WITH LOW PRESSURE AIR.
3.
INSPECT ALL PARTS FOR DAMAGE. REPLACE
PARTS AS REQUIRED.
REASSEMBLY:
1.
REASSEMBLE PINTLE HOOK (1).
a.
Install latch (4) with spring (5) and secure with
pin (8).
b.
Install arm (12) on pintle hook (1).
c.
Install latch bolt (11), hex nut (6) and new cotter
pin (7).
d.
Install new chain (9) and drive screw (10) if
required.
2.
INSTALL PINTLE HOOK (REFER TO PAGE 14-2.)
3.
LUBRICATE PINTLE HOOK. (REFER TO LO 5-
3810-306-12.)
END OF TASK
14-4