Fuel Shut Off Solenoid Bracket Replacement, Bosch P7100 (5-34)
Wiring Guidelines

Maintenance Manual For All-Terrain Crane (ATEC) Diesel Driven, 22 Ton - Vol 2 - Pt2 Page Navigation
  197    198    199    200    201  202  203    204    205    206    207  
img
.
TM 5-3810-307-24-2-2
8 mm, 10 mm
Install in the reverse order of removal.
Adjust the shut off solenoid. Refer to Procedure (5-
29).
Throttle  Lever
Replacement,
Bosch
P7100 (5-36)
8 mm
Remove and replace the throttle lever as illustrated.
NOTE
The throttle is indexed on the throttle shaft
with a Woodruff key.
Shutdown Solenoid Inspection, Bosch
P7100 (5-37)
Engines using the Bosch P7100 fuel injection pump
with the RQVK governor are equipped with the
synchro-start fuel shut off solenoid to actuate the
shut off lever. Both 12 volt and 24 volt external fuel
shut off solenoids are available.
The synchro-start has a weatherpack connector with
3 wires in it.
Description
Weatherpack Port
Color
Black
Ground
`C'
White
Pull In
`B'
Red
Hold In
`A'
5-8 C-1


Privacy Statement