TM 5-3810-207-20/TO 36C23-3-37-12Figure 123. Starter assembly, removal and installation.208. Generator Regulatora.Removal.Remove the generator regulator in asimilar manner as described in paragraph 73.b.Cleaning and Inspection.Clean and inspect thegenerator regulator (par. 73).c.Installation.Install the generator regulator (par.73).d.Test.Test the generator regulator (par. 73).209. Batteries, Cables, and Battery Boxa.Test.(1)Test the batteries with a hydrometer.(2)For hydrometer specific gravitytemperature corrections, refer to TM 5-6140-200-15.(3)Hydrometer readings should be takenbefore adding a battery solution or afteradding a solution and charging thebattery.(4)Replace a defective battery as necessary.Warning:Do not smoke or allow open flamenear charging batteries. Seriousinjury from explosion may result.Avoid spilling battery solution onflesh or clothing.b.Adjustment of Cable Lugs.(1)Place the lug clamp handle in the UPposition.(2)Loosen or tighten the adjusting nut on thelug clamp to make a friction-fit on thebattery post; tighten the locknut.(3)Push the lug clamp handle down parallelto the lug clamp.c.Removal.Remove the batteries, cables, andbattery box as instructed on figure 124.d.Cleaning, Inspection, and Repair.(1)Clean the batteries, cables, and batterybox with an approved solvent and drythoroughly.(2)Inspect the batteries for cracks, leaks, orother damage. Replace a defectivebattery as necessary.165
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business