Figure 185. Control box assembly.
reset button; the circuit breaker should
open within 10 to 125 seconds. If it fails
to meet this requirement, replace the
c. Control Switch.
circuit breaker.
(1) To replace the control switch (11, fig.
(3) To install the circuit breaker, position it on
168), disconnect the electrical leads. Tag
the panel and fasten in place with the two
leads-to facilitate reassembly. Remove
mounting screws. Connect the leads as
the mounting nut from the
AGO 6819A
178