TM 5-3810-295-34
(2) are removed during removal procedures. Note the relative positions send (36), lever housing (59) and drive housing
(40) so these items can be installed in the same position.
b. Remove nuts (3) and (4), lock washers (5), and washer (6). Remove screws (7) and lock washers (8), and
end bell (9). Remove pipe plug (10) and oil wick (11), and expansion plug (12), plug gasket (13) and felt plug (14) from the
end bell.
c. Remove insulated washers (15) from the terminals. Remove screws (16) and lift brushes (17) from the brush
holders.
d. Remove screw and lock washer (18) and lift plate assembly (19) from the end bell. Remove brush hold down
springs (23) from the plate assembly by removing screws (20), lock washers (21) and washers (22). Remove electrical
lead (24) from the assembly.
e. Remove inspection plug (25), plug gasket (26) and adjusting plunger nut (27) from the lever housing. Then
remove retaining ring (28), spring retainer (29), spring (30), spring retainer (31), plunger boot (32) spring retainer washer
(33) and boot clamp (34) from the lever housing.
f.
Remove screws and lock washers (35) and lift solenoid (36) from the housing. Side plunger (37) from
the lever housing.
g. Remove screws (38) and (39) and separate drive housing (40) from lever housing (59). Remove pipe plug
(41) and felt wick (42) from the drive housing. Remove expansion plug (43), gasket (44) and felt plug (45) from the
housing.
h. If necessary, press sleeve bearing (46) from the drive housing.
i.
Remove retaining ring (47) from lever shaft (50), and remove packing (48) and (49), and slide shaft (50) from
lever (52).
j.
Slide drive assembly (51) from the armature shaft. Lever (52) can now be removed from the lever housing.
k. Remove gasket (53) and packing (54) from lever housing (59). Remove spacer washer (55) and brake
washer (56) from the armature shaft.
l.
Remove capscrews (57) and lock washers (58) and separate lever housing (59) from the generator
assembly. Remove pipe plug (60) and felt wick (61) from the lever housing, and remove expansion plug (62), plug gasket
(63) and felt plug (64).
m. Remove sleeve bearing (65) and oil seal (66) from the lever housing. Remove packing (67) from the
generator housing and remove inspection plug (68) and gasket (69).
3-5