TM5-3810-305-103. Connect hoses and wiring harness to rotaryc.manifold using the following procedure:a.b.Relieve pressure in extend-retract valvecircuit by turning ignition switch ON,holding on anti-two block BY-PASSd.switch and operating boom extend-retractlever in both directions several times untilpressure is released. Turn ignition switchOFF.e.Connect extend-retract hoses, hookedunder tabs (Figure 5-13), onto rotarymanifold.f.Remove plugs from winch hoses and stowin tool box. Connect winch hoses H-10and H-11 to connectors on rotary mani-fold.Reconnect wiring harness on collectorring. The anti-two block system is nowoperable.Check to make sure the torque arm stoppin, hoses and wiring harness are all inplace and connected to rotary manifold.Turn hydraulic reservoir cap 1/4 turnclockwise to close reservoir.Figure 5-13. Rotary Manifold Hoses5-41