Figure 10. Check Fan Hub Bearing End Play.
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  128    129    130    131    132  133  134    135    136    137    138  
img
.
TM 5-3810-305-23
0022
Table 1.
Preventive Maintenance Checks and Services (PMCS) - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
f. Add approximately 2 qt (1.89 L) of lubricant.
NOTE
Allow time for lubricant to flow through winch
and then check that lubricant level is at bot-
tom of oil level plug threads.
g. Install oil level plug (Figure 11, Item 1) and new
o-ring (Figure 11, Item 2).
1,2
M0847105
3,4
Figure 11.
Winch Oil Change.
13
Twelve-
Drain and Clean
a. Warm hydraulic oil to operating temperature prior
Month
Hydraulic
to draining.
Check or
Reservoir
Every 1,500
Hours of
Service
b. Position a suitable container under hydraulic
reservoir. Hydraulic reservoir holds 23.8 gal. (90.09 L).
0022-14
03/15/2011Rel(1.8)root(pmcswp)wpno(I00027)