TM 5-3810-305-23
0040
INSTALLATION
WARNING
ADHESIVES AND SEALANTS
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can cause
lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety goggles and
use product in a well-ventilated area away from open flame. If ingested, keep individual calm
and seek medical attention. DO NOT induce vomiting. If contact with skin or eyes is made,
flush thoroughly with water. Dispose of cleanup rags IAW local policy and ordinances.
Failure to follow this warning may cause injury to personnel.
1.
Apply sealing compound to base of oil gage tube (Figure 3, Item 2).
2.
Insert a capscrew into top of oil gage tube (Figure 3, Item 2) and install oil gage tube on block.
Remove capscrew.
3.
Install dipstick (Figure 3, Item 1) into oil gage tube (Figure 3, Item 2).
1
2
M0054105
Figure 3.
Oil Level Gage Installation.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00045)