INSTALLATION - Continued
Low-Pressure Tubes
CAUTION
Make sure injection pump connection is held securely when tightening low-pressure tubes.
Failure to follow this caution may result in damage to equipment.
1.
Install low-pressure tube assembly (Figure 11, Item 1) to injection pump (Figure 11, Item 6) and tighten nut
(Figure 11, Item 7).
2.
Install low-pressure tube (Figure 11, Item 4) to injection pump (Figure 11, Item 6) and tee fitting
(Figure 11, Item 3) and tighten two nuts (Figure 11, Items 2 and 5).
2
1
3
4
7
5
6
M0257105
Figure 11. Low-Pressure Tubes Installation.
03/15/2011Rel(1.8)root(maintwp)wpno(M00055)