• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 5. Battery and Cables Assembly Removal.
Figure 8. Battery and Cables Assembly Installation.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  473    474    475    476    477  478  479    480    481    482    483  
img
. .
TM 5-3810-305-23
0076
REMOVAL - Continued
22.
Remove two screws (Figure 7, Item 1) and lockwashers (Figure 7, Item 2), and disconnect red and blue wires
from shunt (Figure 7, Item 3). Discard lockwashers.
23.
Remove two nuts (Figure 7, Item 4), lockwashers (Figure 7, Item 5), bolts (Figure 7, Item 6), and shunt
(Figure 7, Item 3) from battery box. Discard lockwashers.
24.
Remove four nuts (Figure 7, Item 7), lockwashers (Figure 7, Item 8), bolts (Figure 7, Item 9), and slave
receptacle (Figure 7, Item 10) from battery box. Discard lockwashers.
1,2
3
4,5,6
7,8,9
10
M0097105
Figure 7. Battery and Cables Assembly Removal.
END OF TASK
CLEANING
1.
Clean parts IAW General Maintenance Instructions (WP 0162).
2.
Clean cable terminals with a solution of baking soda and water. Rinse with clean water and wire brush.
3.
Clean batteries with a solution of baking soda and water. Rinse with clean water. Clean negative and positive
terminal posts with a wire brush.
4.
Clean all other parts.
END OF TASK
0076-8
03/15/2011Rel(1.8)root(maintwp)wpno(M00082)