TM 5-3810-305-23
0137
CLEANING
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low
toxicity material. However, it may be irritating to the eyes and skin. Use protective gloves and
goggles. Use in well-ventilated areas. Keep away from open flames and other sources of
ignition. Failure to follow this warning may cause injury to personnel.
1.
Clean parts IAW General Maintenance Instructions (WP 0162).
2.
Clean all parts and surfaces with solvent cleaning compound IAW General Maintenance Instructions
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT directed compressed air against human skin. Failure to follow
this warning may result in injury. Make sure air stream is directed away from user and
other personnel in the area. To prevent injury, personnel must wear protective goggles or
face shield.
3.
Dry parts with compressed air.
END OF TASK
INSPECTION
1.
Inspect parts IAW General Maintenance Instructions (WP 0162). Replace worn or damaged parts.
2.
Polish metal surfaces having minor blemishes with fine crocus cloth.
3.
Coat all parts with clean hydraulic oil.
END OF TASK
0137-3