Figure 4. Rotary Manifold Quick Disconnects (Type II) Removal.
Figure 6. Rotary Manifold Quick Disconnects (Type II) Installation.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  967    968    969    970    971  972  973    974    975    976    977  
img
.
TM 5-3810-305-23
0145
INSTALLATION
WARNING
Weight of manifold is approximately 200 lb (91 kg). Use adequate lifting equipment to lift and
support manifold. DO NOT lift over personnel or let personnel walk underneath suspended
load. Failure to follow this warning may cause injury or death to personnel.
1.
Using hoist and sling, install rotary manifold (Figure 5, Item 7) by lifting manifold over opening in carrier and
lowering down and turning manifold to avoid stop pin ear (Figure 5, Item 4) located on upperstructure.
2.
Align ear on side of manifold (Figure 5, Item 7) to the hole in stop pin ear (Figure 5, Item 4). Install stop pin
(Figure 5, Item 5) and new lockwasher (Figure 5, Item 6) through stop pin ear into manifold.
1
2
3
7
6
5
4
M0455105
Figure 5. Rotary Manifold Quick Disconnects (Type II) Installation.
0145-7