TM 5-3810-306-20
INSTALLATION:
1.
INSTALL COOLANT FILTER (3).
a. Apply a light coat of clean lubricating oil to
gasket.
CAUTION
Do not overtighten coolant filter (3).
Damage to threads may result.
b. Install new coolant filter (3). Hand tighten until
gasket contacts mating surface. Tighten an
additional 1/4-turn.
2.
CHECK RADIATOR COOLANT LEVEL. (REFER
TO TM 5-3810-306-10.)
a. Open shutoff valve (2). Install radiator cap (1).
3.
CONNECT GROUND CABLE AT SHUNT. (REFER
TO PAGE 8-109.)
4.
START ENGINE. (REFER TO TM 5-3810306-10.)
5.
CHECK
FOR
LEAKS
AROUND
SEALING
SURFACES.
6.
SHUT DOWN ENGINE. (REFER TO TM 53810-
306-10.)
END OF TASK
7-15