ELEVATION SWING WARNING SWITCH INSTALLATION
AREA DEFINITION SWITCH - cont
TM-5-3810-306-20 Container Crane 40-Ton Rough Terrain Model RTB75CC Manual
Page Navigation
210
211
212
213
214
215
216
217
218
219
220
TM 5-3810-306-20
AREA DEFINITION SWITCH
TOOLS: General mechanic’s tool kit: automotive (
5180-00-177-7033
)
SUPPLIES:
Lockwashers (Item 7, Appendix C) (2 Required)
Lockwashers (Item 2, Appendix C) (2 Required)
EQUIPMENT CONDITIONS: Boom raised allowing access to area definition switch. (Refer to TM 5-3810-306-10.)
Disconnect ground cable at shunt. (Refer to page 8-109.)
REMOVAL:
1.
REMOVE AREA DEFINITION SWITCH (1) AND
BRACKET (6).
a.
Tag and disconnect electrical connectors (2) to
area definition switch (1).
b.
Remove capscrews (3),
lockwashers
(4) and
flatwashers
(5)
securing
bracket
(6)
to
air/transmission swivel (7). Discard lockwashers
(4).
c.
Remove capscrews (8), flatwashers (9),
lockwashers
(10) and nuts (11) securing area
definition switch (1) to bracket (6). Discard
lockwashers (10).
d.
Remove area switch definition (1).
INSTALLATION:
1.
INSTALL AREA DEFINITION SWITCH (1) AND
BRACKET (6).
a.
Align area definition switch (1) with bracket (6)
holes
and
secure
with
capscrews
(8),
flatwashers (9), new lockwashers (10) and nuts
(11).
8-62