TM 5-3810-306-20
c. Remove center bearing (16) from yoke assembly
(15).
d. Remove four capscrews (12) and lockwashers
(13) from yoke spline flange to free cross and
bearings (10). Discard lockwashers (13).
CLEANING:
WARNING
Dry cleaning solvent P-D-680 is toxic
and flammable. Wear protective
goggles and gloves and use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes and dont
breathe vapors. Do not use near
open flame or excessive heat. Flash
point is 100°F-138°F (38°-59°C). If you
become dizzy while using cleaning
solvent get fresh air immediately and
get medical aid. If contact with eyes
is made, wash your eyes with water
and get medical aid immediately.
WARNING
Compressed air used for cleaning
purposes will not exceed 30 PSI. Use
only with effective chip guarding and
personal
protective
equipment
(goggles/ shield, gloves, etc.).
1.
CLEAN ALL METAL PARTS WITH P-D-680. DRY
WITH COMPRESSED AIR.
2.
INSPECT ALL PARTS FOR DAMAGE. REPLACE
PARTS AS REQUIRED. CROSS AND BEARINGS
MUST BE REPLACED AS A SET.
REASSEMBLY:
1.
LUBRICATE YOKE SPLINES ON PROPELLER
SHAFTS. (REFER TO LO 5-3810-30612).
2.
REASSEMBLE PROPELLER SHAFT(S).
a. Install seal (9) on yoke assembly (8).
b. Align marks and insert yoke spline (2) into yoke
assembly (8).
c. Install cross and bearings (1 and 5) on yoke
spline (2) and yoke assembly (8) using four
10-5