TM 10-1670-298-20&P
Figure 2-31. Initiator Cable Assembly
e. Slide cable end without stop washer through man body guide and secure to main body bracket with bolt.
f.
Reconnect the initiator spread damp and the parachute cable shackles to the eye of the firing head on the M5
cartridge-actuated release assembly and secure with bolt, washer, and nut.
g.
Allow ¼
inch (0.635 cm) slack for both the parachute release and initiator cable assemblies when replacement
is complete.
2-61