TM 10-1670-298-20&P2.26INITIATORCABLEASSEMBLY.This task covers:a.Inspect b.ReplaceINITIAL SETUPToolsReferencesParagraph 2.9Materials/PartsInitiator Cable Assembly (Appendix C)INSPECTConduct a technical/rigger-type inspection In accordance with the instructions contained in paragraph 2 9.REPLACENOTEBe sure that initiator cable stop washer is located next to the firing head of the M5 cartridge-actuated release assemblywhen replacement is completed.a. Remove nut, washer, and bolt connecting the initiator spread clamp and the parachute cable shackles to theeye of the firing head on the M5 cartridge-actuated release assembly (Figure 2-31).b. Remove bolt and disconnect opposite end of cable assembly from bracket on main body of the container.c. Pull end (end without stop washer) of cable assembly through holding damp on main body of container.d. Discard unserviceable cable assembly and replace with serviceable item from stock.2-60
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business